Home > Gallery, Pioneer, Projects / Repairs, Retro Computers and other stuff..., Today, Various > Pioneer LaserActive CLD-A100 – Repair & Modules full Recap

Pioneer LaserActive CLD-A100 – Repair & Modules full Recap

Pioneer LaserActive CLD-A100 - Repair

Pioneer LaserActive CLD-A100 – Repair/Recap & Modules full Recap.

Defects:

  • The Game cartridges on the Sega Genesis Module do not work but the games on CD-ROM work correctly.
  • The INTF Ass’y Interface has some leakage capacitors and in short circuit.
  • The PSU has some leakage capacitors and in short circuit.
  • Solder joint jumped out on the three connectors that connect the two horizzonal/vertical motherboards.
  • Some cold solder on the power stage.

Works that have been done:

  • Cleaning and Full Recap PSU.
  • Cleaning and Full Recap Sega Genesis/Sega CD PAC-S10 Module.
  • Cleaning and Full Recap Nec PC Engine PAC-N1/N1 Module.
  • Cleaning and Recap INTF Ass’y Interface.
  • Rebuilding PADs of the two pcb connectors.
  • Rebuilding cold solder joint on the power stage.

Pioneer LaserActive CLD-A100 Gallery:

Sega Genesis/Sega CD PAC-S10 Module Gallery:

Nec PC Engine PAC-N1/N1 Module Gallery:

  1. Marco C
    June 6th, 2018 at 22:16 | #1

    Glad to have found this area.

  2. Bill S
    December 5th, 2018 at 19:29 | #2

    Hi, can you recap my gear. I have the Sega won’t play cart but will play CD issue, No color on the CLD-A100 and LD wont spin.

  3. Gary
    May 20th, 2020 at 03:18 | #3

    Hello, my pioneer CLD A100 LD and CD wont spin. the N10 fuses have burnt on board (both). I have changed all cap on PSU board and N10 fuses have burnt again. do you know what is the root cause? Many Thanks

  4. May 21st, 2020 at 09:35 | #4

    @Gary

    Hi Gary, replace all capacitors also on the INTF Ass’y Interface.

*